GH.OPS.320 Potable water servicing

Commission Delegated Regulation (EU) 2025/20 · Regulations (EU) 2025/23 and 2025/24 · EAR revision 5 Nov 2025

IRImplementing rule

GH.OPS.320Potable water servicing

The procedures for potable water servicing shall comply with the requirements laid down in point GH.OPS.005 and also with the following additional requirements:

(a)liaising with the aerodrome operator to ensure the following:

(1)all water, for drinking and other personal use, uplifted into the aircraft is free from chemical substances and microorganisms;

(2)potable water quality test is conducted periodically in accordance with the local health authorities and as per the aircraft operator’s procedure;

(b)observing the requirements laid down in the applicable Union legal acts regarding personal protection equipment for the personnel performing potable water servicing;

(c)properly mitigating the risk of producing FOD during this activity.

IR · GH.OPS.320 — Regulations (EU) 2025/23 and 2025/24 · Regulation (EU) 2025/20 · Ground Handling Easy Access Rules · EAR revision 5 Nov 2025

AMCAcceptable means of compliance

AMC1 GH.OPS.320Potable water servicing

Show the text

POTABLE WATER TESTING, CHEMICAL SUBSTANCES AND GSE

(a)The GH organisation should ensure that regular tests are performed on the potable water at various water transfer points before it is uplifted into the aircraft potable water reservoir. Evidence of such tests should be kept in accordance with the documents and records requirements.

(b)The chemical composition of the water to be uplifted into the aircraft potable water reservoir should meet the standards set by the World Health Organization or the relevant state authority, whichever is more stringent.

(c)The potable water should be free from any unnecessary chemical substances and microorganisms. It may be treated with suitable disinfectants such as those based on chlorine or hydrogen peroxide. Ozone may also be present after further treatment, to provide additional disinfection and protection against microbiological contaminants.

(d)The potable water servicing equipment should be maintained in accordance with the GSE maintenance programme. The truck should be clearly identified as ‘drinking/potable water for aircraft’ and regularly cleaned and disinfected in accordance with the applicable standards. When not in use, the potable water truck should be parked in an area different from the one where other GSE with nonpotable water is parked.

(e)The GH organisation should apply any other additional instructions of the aircraft operator.

AMC · AMC1 GH.OPS.320 — Regulations (EU) 2025/23 and 2025/24 · ED Decision 2025/007/R · Ground Handling Easy Access Rules · EAR revision 5 Nov 2025

All rules in Annexes

Consolidated from the EASA Easy Access Rules (revision 5 Nov 2025, extracted 17 Aug 2026) for convenience. Not the official publication — verify against the Official Journal of the European Union and the EASA publications before operational use.

Ask Metis about GH.OPS.320 →

Metis opens with Avioverse in October 2026 · request early access.