CS 25.1395Maximum intensities in over-lapping beams of forward and rear position lights
No position light intensity may exceed the applicable values in the following table, except as provided in CS 25.1389(b)(3):
| Overlaps | Maximum intensity | |
|---|---|---|
| Area A candela (candles) | Area B candela (candles) | |
| Green in dihedral angle L | 10 | 1 |
| Red in dihedral angle R | 10 | 1 |
| Green in dihedral angle A | 5 | 1 |
| Red in dihedral angle A | 5 | 1 |
| Rear white in dihedral angle L | 5 | 1 |
| Rear white in dihedral angle R | 5 | 1 |
Where –
(a)Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10° but less than 20°; and
(b)Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20°.
IR · CS 25.1395 — CS-25 · ED Decision 2003/2/RM · CS-25 Easy Access Rules · EAR revision 26 Jan 2023