AWO.B.CATIII.109 CS AWO.B.CATIII.109 Alert height

All Weather Operations (CS-AWO) · CS-AWO · EAR revision 14 Aug 2026

IRImplementing rule

AWO.B.CATIII.109CS AWO.B.CATIII.109 Alert height

(See AMC AWO.B.CATIII.109)

For a fail-operational system with a DH below 15 m (50 ft) or with no DH, an alert height shall be established in accordance with CS AWO.B.CATIII.123(a) and shall be at least 30 m (100 ft).

[Issue: CS-AWO/2]

IR · AWO.B.CATIII.109 — CS-AWO · CS-AWO Easy Access Rules · EAR revision 14 Aug 2026

AMCAcceptable means of compliance

AMC AWO.B.CATIII.109 Alert height

Show the text

(See CS AWO.B.CATIII.109)

It may be operationally useful for the alert height to be somewhat higher than 30 m (100 ft) since this would permit reversion to a higher DH in the event of system failure. A maximum value should be established during certification and it should not normally be above 90 m (300 ft).

[Issue: CS-AWO/2]

AMC — CS-AWO · CS-AWO Easy Access Rules · EAR revision 14 Aug 2026

All rules in SUBPART B -APPROACH AND LANDING SECTION 4 -AIRWORTHINESS CERTIFICATION OF AEROPLANES FOR OPERATIONS WITH DECISION HEIGHTS (DHs) BELOW 30 M (100 FT) OR NO DECISION HEIGHT (DH) -CATEGORY III (CAT III) OPERATIONS

Consolidated from the EASA Easy Access Rules (revision 14 Aug 2026, extracted 17 Aug 2026) for convenience. Not the official publication — verify against the Official Journal of the European Union and the EASA publications before operational use.