NCC.IDE.A.205 Hand fire extinguishers

ANNEX VI (Part-NCC) · Regulation (EU) No 965/2012 · EAR revision 27 Mar 2026

IRImplementing rule

NCC.IDE.A.205Hand fire extinguishers

(a)Aeroplanes shall be equipped with at least one hand fire extinguisher:

(1)in the flight crew compartment; and

(2)in each passenger compartment that is separate from the flight crew compartment, except if the compartment is readily accessible to the flight crew.

(b)The type and quantity of extinguishing agent for the required fire extinguishers shall be suitable for the type of fire likely to occur in the compartment where the extinguisher is intended to be used and to minimise the hazard of toxic gas concentration in compartments occupied by persons.

IR · NCC.IDE.A.205 — Regulation (EU) No 965/2012 · Regulation (EU) No 800/2013 · Air OPS Easy Access Rules · EAR revision 27 Mar 2026

AMCAcceptable means of compliance

AMC1 NCC.IDE.A.205Hand fire extinguishers

Show the text

NUMBER, LOCATION AND TYPE

(a)The number and location of hand fire extinguishers should be such as to provide adequate availability for use, account being taken of the number and size of the passenger compartments, the need to minimise the hazard of toxic gas concentrations and the location of toilets, galleys, etc. These considerations may result in the number of fire extinguishers being greater than the minimum required.

(b)There should be at least one hand fire extinguisher installed in the flight crew compartment and this should be suitable for fighting both flammable fluid and electrical equipment fires. Additional hand fire extinguishers may be required for the protection of other compartments accessible to the crew in flight. Dry chemical fire extinguishers should not be used in the flight crew compartment, or in any compartment not separated by a partition from the flight crew compartment, because of the adverse effect on vision during discharge and, if conductive, interference with electrical contacts by the chemical residues.

(c)Where only one hand fire extinguisher is required in the passenger compartments, it should be located near the cabin crew member’s station, where provided.

(d)Where two or more hand fire extinguishers are required in the passenger compartments and their location is not otherwise dictated by consideration of (a), an extinguisher should be located near each end of the cabin with the remainder distributed throughout the cabin as evenly as is practicable.

(e)Unless an extinguisher is clearly visible, its location should be indicated by a placard or sign. Appropriate symbols may also be used to supplement such a placard or sign.