IRImplementing rule
CS HPT-DSN.B.120Touchdown and lift-off areas (TLOFs)
(a)General:
(1)At least one TLOF should be provided at a heliport.
(2)One TLOF should be located within the FATO or one or more TLOFs should be collocated with helicopter stands.
(b)Characteristics:
(1)A TLOF should be of sufficient size to contain a circle of diameter of at least 0.83 D of the largest helicopter the area is intended to serve.
(2)Where the TLOF is within the FATO, the TLOF should be dynamic load-bearing.
(3)Where a TLOF is collocated with a helicopter stand, the TLOF should be static load-bearing and be capable of withstanding the traffic of the helicopters that the area is intended to serve.
(4)Slopes on a TLOF should be sufficient to prevent accumulation of water on the surface of the area and should not exceed 2 per cent in any direction.
(5)Where a TLOF is located within a FATO which can contain a circle of diameter more than 1 D, the centre of the TLOF should be located not less than 0.5 D from the edge of the FATO.
IR · CS HPT-DSN.B.120 — Regulation (EU) No 139/2014 · ED Decision 2019/012/R · Aerodromes Easy Access Rules · EAR revision 13 Mar 2026