IRImplementing rule
ETSO-C99a
FLIGHT DECK (SEDENTARY) CREW MEMBER PROTECTIVE BREATHING EQUIPMENT
1 Applicability
This ETSO provides the requirements which Flight Deck (Sedentary) Crew Member Protective Breathing Equipment that are designed and manufactured on or after the date of this ETSO must meet in order to be identified with the applicable ETSO marking.
2 Procedures
- 2.1 General
Applicable procedures are detailed in CS-ETSO, Subpart A.
- 2.2 Specific
None.
3 Technical Conditions
- 3.1 Basic
3.1.1 Minimum Performance Standard
Standards set forth in the SAE AS8031A, Personal Protective Devices for Toxic and Irritating Atmospheres Air Transport Flight Deck (Sedentary) Crew members, dated 3/1/1999 as amended by Appendix 1 to this ETSO.
3.1.2 Environmental Standard
To be tested in accordance with the procedures in SAE AS8026A, Crewmember Demand Oxygen Mask for Transport Category Aircraft, dated July 1996, paragraph 4.5.
3.1.3 Computer Software
None.
- 3.1.4 Electronic Hardware Qualification
None.
- 3.2 Specific
None.
3.2.1 Failure Condition Classification
See CS-ETSO, Subpart A, paragraph 2.4.
4 Marking
- 4.1 General
Marking as detailed in CS-ETSO, Subpart A, paragraph 1.2.
- 4.2 Specific
In addition to 4.1, the mask assembly shall be marked with the following:
- (1) Size (if more than one size is manufactured), - (2) Type (as specified in ETSO-C89a, paragraph 3), and - (3) 'Beards will not seal', if applicable.
5 Availability of Referenced Document
See CS-ETSO, Subpart A, paragraph 3.
[Amdt ETSO/11]
APPENDIX 1 TO ETSO-C99A -MPS FOR FLIGHT DECK (SEDENTARY) CREW MEMBER PROTECTIVE BREATHING EQUIPMENT
ED Decision 2016/013/R
The applicable standard is SAE AS8031A, Personal Protective Devices for Toxic and Irritating Atmospheres Air Transport Flight Deck (Sedentary) Crewmembers, dated March 1999. It shall be modified as follows:
| AS8031A section: | Action: |
|---|---|
| Section 1, SCOPE | To be disregarded. |
| Paragraph 7.1 a. Resistance to Flammability | To be revised: The device shall be designed, including packaging, (except small parts like knobs, triggers, fasteners, seals, and electrical parts) of materials that don't contribute significantly to the propagation of a fire, and that comply with CS 25.853(a), Appendix F, Part I(a)(1)(iv). |
| Paragraph 7.1j | To be revised: 'ANSI/ASSE Z87.1 - 2003, 'Occupational and Educational Eye and Face Protection Devices.'' |
| Paragraph 7.1k | To be revised: 'ANSI/ASSE Z87.1 - 2003, (Table 8) 'Optical Quality, Normal Corrective Vision.' Clear versus yellow tint and vision distortion testing for thermal protection.' |
| Paragraph 8.1 | To be revised: 'Cleaning and Sterilising: Except for non -reusable or disposable systems, it must be ensured that cleaning and sterilising the device is possible without major disassembly and adverse effects on operation and performance. The cleaning method must be either manufacturer- recommended, or according to SAE ARP 1176, Oxygen System Component Cleaning and Packaging. Cleaning and sterilising procedures shall be included i n the CMM.' |
| Section 8, IDENTIFICATION | To be disregarded except of paragraph 8h |
| Paragraph 9.1 | The following values shall be used: X=.05, Y=.10 and Z=.05. |
| Paragraph 10.1 For Flight deck Crewmembers | To be revised: An integral microphone shall be included in the protective device when it is necessary to allow the user to communicate (speak) through the aircraft's communication system. The microphone must be approved or meet the requirements of ETSO-C139a or later. |
[Amdt ETSO/11]
IR · ETSO-C99a — CS-ETSO · ED Decision 2016/013/R · CS-ETSO Easy Access Rules · EAR revision 14 Aug 2026