IRImplementing rule
CS 25.971Fuel tank sump
(a)Each fuel tank must have a sump with an effective capacity, in the normal ground attitude, of not less than the greater of 0·10% of the tank capacity or one-quarter of a litre unless operating limitations are established to ensure that the accumulation of water in service will not exceed the sump capacity.
(b)Each fuel tank must allow drainage of any hazardous quantity of water from any part of the tank to its sump with the aeroplane in the ground attitude.
(c)Each fuel tank sump must have an accessible drain that –
(1)Allows complete drainage of the sump on the ground;
(2)Discharges clear of each part of the aeroplane; and
(3)Has manual or automatic means for positive locking in the closed position.
IR · CS 25.971 — CS-25 · ED Decision 2003/2/RM · CS-25 Easy Access Rules · EAR revision 26 Jan 2023