CS 25.858 Cargo or baggage compartment smoke or fire detection systems

Large Aeroplanes (CS-25) · CS-25 · EAR revision 26 Jan 2023

IRImplementing rule

CS 25.858Cargo or baggage compartment smoke or fire detection systems

If certification with cargo or baggage compartment smoke or fire detection provisions is requested, the following must be met for each cargo or baggage compartment with those provisions:

(a)The detection system must provide a visual indication to the flight crew within one minute after the start of a fire.

(b)The system must be capable of detecting a fire at a temperature significantly below that at which the structural integrity of the aeroplane is substantially decreased.

(c)There must be means to allow the crew to check in flight, the functioning of each smoke or fire detector circuit.

(d)The effectiveness of the detection system must be shown for all approved operating configurations and conditions.

[Amdt 25/3]

IR · CS 25.858 — CS-25 · ED Decision 2007/010/R · CS-25 Easy Access Rules · EAR revision 26 Jan 2023