UAM.IDE.MVCA.250 Handheld fire extinguishers

ANNEX IX (Part-IAM) · Regulation (EU) No 965/2012 · EAR revision 27 Mar 2026

IRImplementing rule

UAM.IDE.MVCA.250Handheld fire extinguishers

(a)The VCA shall be equipped with at least one handheld fire extinguisher in the flight crew compartment, which shall be readily accessible for use.

(b)At least one handheld fire extinguisher shall be located in the passenger compartment if the handheld fire extinguisher located in the flight crew compartment cannot be easily accessed by the passengers.

(c)The type and quantity of the fire-extinguishing agent of the handheld fire extinguishers shall be suitable for the type of fire likely to occur in the compartment where the handheld fire extinguisher is intended to be used and to minimise the hazard of toxic gas concentration in compartments occupied by persons.

IR · UAM.IDE.MVCA.250 — Regulation (EU) No 965/2012 · Regulation (EU) 2024/1111 · Air OPS Easy Access Rules · EAR revision 27 Mar 2026

AMCAcceptable means of compliance

AMC1 UAM.IDE.MVCA.250Handheld fire extinguishers

Show the text

QUANTITY, LOCATION, AVAILABILITY AND TYPES

(a)The quantity and location of handheld fire extinguishers should be such as to provide adequate availability for use in each compartment accessible in flight, account being taken of the need to minimise the hazard of toxic gas concentrations.

(b)Handheld fire extinguishers should be checked to make sure that:

(1)they are in place and secured;

(2)they are charged and pressurised; and

(3)their expiry date has not elapsed.

(c)Unless a handheld fire extinguisher is clearly visible, its location should be indicated by a placard or sign. Appropriate symbols may also be used to complement placards or signs.

(d)Handheld fire extinguishers should be suitable for the types of fire likely to occur in the compartment where they are intended to be used.

(e)Dry chemical fire extinguishers should not be used in the flight crew compartment or in any passenger cabin which is not separated by a partition from the flight crew compartment, because of the adverse effect on vision during discharge and, if conductive, interference with electrical contacts by the chemical residues.

(f)Passengers should be instructed on how to use the handheld fire extinguisher when necessary.

AMC · AMC1 UAM.IDE.MVCA.250 — Regulation (EU) No 965/2012 · ED Decision 2025/010/R · Air OPS Easy Access Rules · EAR revision 27 Mar 2026

All rules in SUBPART D — INSTRUMENTS, DATA AND EQUIPMENT

Consolidated from the EASA Easy Access Rules (revision 27 Mar 2026, extracted 17 Aug 2026) for convenience. Not the official publication — verify against the Official Journal of the European Union and the EASA publications before operational use.

Ask Metis about UAM.IDE.MVCA.250 →

Metis opens with Avioverse in October 2026 · request early access.