IRImplementing rule
CS 26.160Lavatory fire protection
Compliance with point 26.160 of Part-26 is demonstrated by complying with CS 25.854, or equivalent or with the following:
(a)Each lavatory is equipped with a smoke detector system or equivalent that provides a warning light in the cockpit, or provides a warning light or audible warning in the passenger cabin that would be readily detected by a cabin crew member; and
(b)Each lavatory is equipped with a built-in fire extinguisher for each disposal receptacle for towels, paper, or waste, located within the lavatory. The extinguisher is designed to discharge automatically into each disposal receptacle upon occurrence of a fire in that receptacle.
[Issue: 26/3]
IR · CS 26.160 — Regulation (EU) 2015/640 · ED Decision 2020/023/R · Part-26 Easy Access Rules · EAR revision 20 Mar 2026